REN Hui, LIU Guang-hua, LI Bei. Test and Determination of Trace Potassium in Pure Rhenium by AAS[J]. Failure Analysis and Prevention, 2015, 10(6): 389-392. DOI: 10.3969/j.issn.1673-6214.2015.06.011
    Citation: REN Hui, LIU Guang-hua, LI Bei. Test and Determination of Trace Potassium in Pure Rhenium by AAS[J]. Failure Analysis and Prevention, 2015, 10(6): 389-392. DOI: 10.3969/j.issn.1673-6214.2015.06.011

    Test and Determination of Trace Potassium in Pure Rhenium by AAS

    • A method for the determination of trace K in pure rhenium by AAS has been developed. The measuring conditions of AAS have been optimized. The influences of the amount of HNO3 and rhenium on the determination of K in pure rhenium have been investigated. The relative standard deviations of the results obtained by AAS method are lower than 9.04%, the appropriate concentration range is 0.000 1%~0.001% and the detection limit is 0.0035 μg·mL-1. The method is not only accurate and reliable but also simple and rapid.