袁锦科, 黄彩清. 聚焦离子束双束系统在微机电系统失效分析中的应用[J]. 失效分析与预防, 2021, 16(4): 251-256. DOI: 10.3969/j.issn.1673-6214.2021.04.006
    引用本文: 袁锦科, 黄彩清. 聚焦离子束双束系统在微机电系统失效分析中的应用[J]. 失效分析与预防, 2021, 16(4): 251-256. DOI: 10.3969/j.issn.1673-6214.2021.04.006
    YUAN Jin-ke, HUANG Cai-qing. Application of Focused Ion Beam Dual Beam System in Failure Analysisof Micro Electro Mechanical System[J]. Failure Analysis and Prevention, 2021, 16(4): 251-256. DOI: 10.3969/j.issn.1673-6214.2021.04.006
    Citation: YUAN Jin-ke, HUANG Cai-qing. Application of Focused Ion Beam Dual Beam System in Failure Analysisof Micro Electro Mechanical System[J]. Failure Analysis and Prevention, 2021, 16(4): 251-256. DOI: 10.3969/j.issn.1673-6214.2021.04.006

    聚焦离子束双束系统在微机电系统失效分析中的应用

    Application of Focused Ion Beam Dual Beam System in Failure Analysisof Micro Electro Mechanical System

    • 摘要: MEMS惯性传感器是一种将运动物理量转换成电信号的传感器,其工作原理涉及物理学、机械学、微电子学科等。随着MEMS芯片尺寸的不断缩小和性能的不断提高,传统的半导体失效分析方法已很难满足MEMS器件失效分析的需求。本研究结合MEMS器件的工作原理和FIB双束系统的特点,通过聚焦FIB双束系统分析MEMS芯片中3种常见的失效形式,即产品存在漏电流、灵敏度异常和零输入偏差漂移等,分析得出MEMS芯片中常见的几种失效模式包括电极结构损坏、晶圆制造过程中引入的硅颗粒等典型失效模式,在此过程中展现出FIB双束系统在MEMS失效分析中特有的灵活性和优越性。

       

      Abstract: Inertial sensors of micro electro mechanical system(MEMS) are a kind of sensors transforming physical quantity of motion into electrical signal. Their working principles include the disciplines of physics, mechanics, microelectronics and so on. With the continuous size reduction and performance improvement of MEMS chips, traditional semiconductor failure analysis methods can hardly meet the demand of MEMS device failure analysis. In this paper, the working principles of MEMS devices and focused ion beam(FIB) dual beam system were discussed, and three common failure phenomena of MEMS chips were analyzed by focusing on FIB dual beam system, namely current leakage, abnormal sensitivity and zero input offset drift. It is found that the common failure modes of MEMS chips include electrode structure damage, silicon particle inducing during wafer manufacturing, and so on. During this process, the flexibility and superiority of FIB dual beam system in MEMS failure analysis are presented.

       

    /